Reconstruction
Efficiency, Wheel -1, MB2.

Notes:
Sector 3. Poor efficiency in Phi2: average layer efficiency ~94% 
This is due to last ~20 cells: see below the efficiency wire by wire 
and 
here
 
the efficiency as a function
of drift distance for a group of faulty cells. 
 Probably bad gas conditions 
during data taking. 
 (In fact much better behaviour at 
sector commissioning
 
may 2007)
Sector 9. Poor efficiency in sl theta: average layer efficiency ~90% 
Efficiency uniform within the chamber (see below the efficiency wire by wire) 
and here
 the efficiency as a function
of drift distance. 
 
Poor efficiency also in Phi2: average layer efficiency ~96% 
This is due to first ~20 cells: see below the efficiency wire by wire 
 
and here
 the efficiency as a function
of drift distance for a group of faulty cells. 
Bad gas conditions during data taking?
Mean Layer Efficiency, Wheel -1, MB2

Number of dead channels per layer. Wheel -1, MB2

Single wire efficiencies, Wheel -1, MB2
Sector 2,sl_1
Sector2,sl_2
Sector2,sl_3
Sector3,sl_1
Sector3,sl_2
Sector3,sl_3
Sector4,sl_1
Sector4,sl_2
Sector4,sl_3
Sector5,sl_1
Sector5,sl_2
Sector5,sl_3
Sector6,sl_1
Sector6,sl_2
Sector6,sl_3
Sector8,sl_1
Sector8,sl_2
Sector8,sl_3
Sector9,sl_1
Sector9,sl_2
Sector9,sl_3
Sector10,sl_1
Sector10,sl_2
Sector10,sl_3
Sector11,sl_1
Sector11,sl_2
Sector11,sl_3
Sector12,sl_1
Sector12,sl_2
Sector12,sl_3